- September 30th: SUNET performed a preemptive emergency maintenance on the core router in Malmö to ensure network stability.
- September 26th: Provider performed reconstruction of switchgear maintenance in Trollhättan.
- September 26th: Fiber provider performed planned cable splice maintenance.
- September 24th: Provider performed planned hardware conversion in Trollhättan.
- September 24th: SUNET routers du-r22, hh-r21, lnd88-r11, lnu-v-r21, mau-r21 and mdu-r22 were upgraded to a newer software release.
- September 23rd: Provider performed emergency cable repairs that affected the link between Odensala - Stockholm.
- September 23rd: SUNET routers lba-r11, ltu-r21, su-r21 and trh-r11 were upgraded to a newer software release.
- September 19th: SUNET updated the configuration to prevent routing loops in the network. The change did not produce the desired effect and was rollbacked.
- September 19th: The site owner together with the power provider replaced the UPS batteries at the site in Luleå (LLA1).
- September 19th: SUNET routers cth-r21, his-r21, hj-r22, kir3-r11 and lnu-k-r22 were upgraded to a newer software release. Bos-r11 was postponed due to time restrictions.
- September 18th: The provider performed a Fiber Maintenance between Karsefors - Mörarp.
- September 18th: SUNET deployed active live monitoring units for all fiber stretches on the circuit going through Odensala.
- September 18th: We migrated [https://bankid-idp.sunet.se/], [md.fidus.skolverket.se|http://md.fidus.skolverket.se/] and [ds.fidus.skolverket.se. |http://ds.fidus.skolverket.se/]
- September 18th: SUNET routers bth-r22, gu-r21, kth-r21, oru-r22, ske109-r11 and tug-r11 were upgraded to a newer software release.
- September 17th: SUNET routers gbg7-r11, hb-r22, kau-r22, liu-r22, lnu-v-r22 and lu-r22 were upgraded to a newer software release.
- September 16th: SUNET performed software maintenance on hv-r22, jkg-r11, umu-r22 and uu-r22.
- September 12th: Supplier perform cable splice in MIdskog that affected the link between Östersund - Midskog.
- September 11th: SUNET performed software maintenance on lla1-r11.
- September 11th: SUNET performed software maintenance on gu-r22, kmr88-r11, su-r22 and vxj-r11.
- September 10th: SUNET performed software maintenance on cth-r22, hkr-r22, kar1-r11 and mau-r22.
- September 9th: SUNET performed software maintenance on nkg188-r11, his-r22, fln4-r11 and ltu-r22.
- September 5th: Provider performed a fiber maintenance in MIdskog that affected the link between Östersund - Midskog.
- September 5th: SUNET router hig-r22 was upgraded to a new software release.
- September 4th: Provider performed a cable maintenance in Norrköping. This affected one of the connections to SMHI.
- September 4th: A maintenance was carried out to move a transit link between SUNET - NORDUnet to another router.
- September 4th: SUNET performed softare maintenance on ksd1-r11 and hj-r21.
- September 3rd: A planned maintenance to deploy active live monitoring units for all fiber stretches on the circuit going through Västerås and Hamra has been completed.
- September 3rd: SUNET deployed active live monitoring units for all fiber stretches on the circuit going through Västerås and Hamra.
- September 1st: Provider performed maintenance affecting VPN service in to Göteborg.
- September 1st: Provider performed fiber maintenance between Hedenlunda - Kolbotten. No outage recorded.
Scope | Unscheduled | Scheduled | Total |
---|---|---|---|
Hardware | 3 pcs 01:50 | 1 pcs | 4 pcs 01:50 |
Link | 5 pcs 23:23 | 15 pcs 1d 08:00 | 20 pcs 2d 07:23 |
Other | 0 pcs | 0 pcs | 0 pcs |
Routing | 0 pcs | 1 pcs | 1 pcs |
Software | 0 pcs | 1 pcs | 1 pcs |